GAON CABLE CO. Genuine & OEM spare parts made in Japan, China, Korea and Europe for Maritime, Oil & Gas Industry.
Contact us if you are looking for Cable and Pipe Transits NTFIRE SYSTEM – MFIMATE Sleeve and MFISEAL Sealant marine equipment and ship spare parts.
Equipment: Cable and Pipe Transits
Manufacturer: GAON CABLE CO.
Type / Model / Part no: NTFIRE SYSTEM – MFIMATE Sleeve and MFISEAL Sealant
Technical Specification & Spare Parts:
NTFIRE SYSTEM – MFIMATE Sleeve and MFISEAL Sealant Cable and Pipe Transits GAON CABLE CO.
Electric Cables and Accessories,
Cable and Pipe Transits,
Cable and Pipe Transits,
NTFIRE SYSTEM is made of MFIMATE sleeve (placed around cable and filled at penetration) and MFISEAL sealant (sealed on both side at penetration surface 20mm thickness layer),
1. Symmetry type cable transit for A-60 class bulkhead and deck | a) Rectangle type: | – max. size 640W x 350H x 180D (cross sectional area: 210,118mm2) | – min. size 180W x 120H x 180D (cross sectional area: 15,640mm2) | – max. cable filling available up to 40% of the internal cross-sectional area of protective casing | b) Circular type: | – max. size 200A x 180D (cross sectional area:36,745mm2) | – min. size 50A x 180D (cross sectional area: 2,874mm2) | – max. cable filling available up to 45% of the internal cross-sectional area of protective casing | 2. Asymmetry type cable transit for A-60 class deck | a) Rectangle type: | – max. size 640W x 350H x 180D (cross sectional area: 210,118mm2) | – min. size 180W x 120H x 180D (cross sectional area: 15,640mm2) | – cable filling available up to 40% of the internal cross-sectional area of protective casing | b) Circular type: | – max. size 200A x 180D (cross sectional area: 36,745mm2) | – min. size 50A x 180D (cross sectional area: 2,874mm2) | – cable filling available up to 45% of the internal cross-sectional area of protective casing | 3. Symmetry type cable transit for A-0 class bulkhead and deck | a) Rectangle type: | – max. size 600W x 300H x 180D (cross sectional area: 180,000mm2) | – min. size 100W x 80H x 180D (cross sectional area: 8,000mm2) | – max. cable filling available up to 40% of the internal cross-sectional area of protective casing | b) Circular type: | – max. size 300A x 180D (cross sectional area:79,672mm2) | – max. size 200A x 180D (cross sectional area:36,745mm2) | – min. size 50A x 180D (cross sectional area: 2,874mm2) | – min. size 32A x 180D (cross sectional area: 1,432mm2) | – max. cable filling available up to 43% of the internal cross-sectional area of protective casing | 4. A class division bulkhead and deck transit for Water & Gas-Tightness | – Water-tightness up to pressure of 3.5 bar | – Gas-tightness up to pressure of 0.3 bar | Note) Abbreviation W: Width, H: Height, D: Depth,
International Convention for the Safety of Life at Sea (SOLAS), Consolidated Edition 2014 II-2/Reg.9.3 IMO 2010 FTP Code Part 3 Resolution MSC.307(88) (adopted 1 July 2012) Annex 1, Part 3 Appendix 2 A.IV Cable Transits,
Contact our Customer Care Center today for quotations and orders.
Shipcare+ Japan
[email protected]
www.shipcare.jp