OMRON SOCIAL SOLUTIONS Co.,Ltd. Genuine & OEM spare parts made in Japan, China, Korea and Europe for Maritime, Oil & Gas Industry.
Contact us if you are looking for Circuit Breakers S800S B, C, D and K Characteristics, Auxilliary Contacts to S800 series Circuit Breakers S800-AUX & AUX/ALT, Current Limiter S803S-SCL, Current Limiter S803x-SCL-SR marine equipment and ship spare parts.
Equipment: Circuit Breakers
Manufacturer: OMRON SOCIAL SOLUTIONS Co.,Ltd.
Type / Model / Part no: S800S B, C, D and K Characteristics, Auxilliary Contacts to S800 series Circuit Breakers S800-AUX & AUX/ALT, Current Limiter S803S-SCL, Current Limiter S803x-SCL-SR
Technical Specification & Spare Parts:
S800S B, C, D and K Characteristics, Auxilliary Contacts to S800 series Circuit Breakers S800-AUX & AUX/ALT, Current Limiter S803S-SCL, Current Limiter S803x-SCL-SR Circuit Breakers OMRON SOCIAL SOLUTIONS Co.,Ltd.
Switchgear and Components,
Circuit Breakers,
Circuit Breakers,
S800 B, C or D characteristics for circuit protection. S800 K characteristic for motor protection. Circuit breakers series 800 series and current limiter 803S-SCL and 803x-SCL-SR. S800S B* S800S C* S800S D* Rated insulation voltage Ui (V) 690 690 690 Rated impulse withstand voltage Uimp (kV) 8 8 8 Rated current (A) at 30OC** 10-125 10-125 10-125 Rated voltage (V) 230-690 230-690 230-690 Rated frequency (Hz) 50-60 50-60 50-60 Breaking current (kA) ICU, 415 V 50 kA 50 kA 50 kA Breaking current (kA) ICU, 440 V 30kA 30kA 30kA Breaking current (kA) ICU, 500 V 10-80 A: 15 kA 100-125 A: 10 kA 10-80 A: 15 kA 100-125 A: 10 kA 10-80 A: 15 kA 100-125 A: 10 kA Breaking current (kA) ICU, 690 V 10-80 A: 6 kA 100-125 A: 4,5kA 10-80A: 6 kA 100-125A: 4,5kA 10-80A: 6 kA 100-125A: 4,5kA Breaking current (kA) ICS, 415 V 40 kA 40 kA 40 kA Breaking current (kA) ICS, 440 V 10-80 A: 22,5 kA 100 A: 15 kA 125 A: 5 kA 10-80 A: 22,5 kA 100 A: 15 kA 125 A: 5 kA 10-80 A: 22,5 kA 100 A: 15 kA 125 A: 5 kA Breaking current (kA) ICS, 500 V 5 kA 5 kA 5 kA Breaking current (kA) ICS, 690 V 10-80 A: 4 kA 100-125 A: 3 kA 10-80 A: 4 kA 100-125 A: 3 kA 10-80 A: 4 kA 100-125 A: 3 kA Utilisation category A A A Thermal release 1.13-1,45 x In 1.13-1,45 x In 1.13-1,45 x In Electromagnetic release 3-5 x In 5-10 x In 10-20 x In S800S K* S803S-SCL S803x-SCL-SR Rated insulation voltage Ui (V) 690 690 690 Rated impulse withstand voltage Uimp (kV) 8 8 8 Rated current (A) at 30OC** 10-125 32-125 32-100 Rated voltage (V) 230-690 440-690 440-690 Rated frequency (Hz) 50-60 50-60 50-60 Breaking current (kA) ICU, 415 V 50 kA 100 kA – Breaking current (kA) ICU, 440 V 30kA 100kA – Breaking current (kA) ICU, 500 V 10-80 A: 15 kA 100-125 A: 10 kA 50 kA – Breaking current (kA) ICU, 690 V 10-80 A: 6 kA 100-125 A: 4,5 kA 50 kA 50 kA Breaking current (kA) ICS, 415 V 40 kA 100 kA – Breaking current (kA) ICS, 440 V 10-80 A: 22,5 kA 100 A: 15 kA 125 A: 5 kA 100kA – Breaking current (kA) ICS, 500 V 5 kA 50 kA – Breaking current (kA) ICS, 690 V 10-80 A: 4 kA 100-125 A: 3 kA 50 kA 50 kA Utilisation category A A A Thermal release 1.05-1,2 x In – – Electromagnetic release 10-14 x In – – * = 1, 2, 3 or 4 for 1-4 poles with B, C, D or K characteristics. ** Rated current: 10, 13, 16, 20, 25, 32, 40, 50, 63, 80, 100 or 125 A given for Ambient temperature of 30ºC. For 45ºC nominal currents are slightly reduced according to Technical Catalogue page. 3/3. For ship application, thermal release data shall be multiplied with correction factors ? 0,9 for characteristics B,C and D ? 0,96 for characteristic K IP Class 40,
Contact our Customer Care Center today for quotations and orders.
Shipcare+ Japan
[email protected]
www.shipcare.jp