{"id":575713,"date":"2022-12-29T02:34:58","date_gmt":"2022-12-29T02:34:58","guid":{"rendered":"https:\/\/shipcare.jp\/crankcase-explosive-conditions-monitoring-system-neuenhauser-kompressorenbau-gmbh-tufmon-mev282-and-mev283\/"},"modified":"2022-12-29T02:34:58","modified_gmt":"2022-12-29T02:34:58","slug":"crankcase-explosive-conditions-monitoring-system-neuenhauser-kompressorenbau-gmbh-tufmon-mev282-and-mev283","status":"publish","type":"post","link":"https:\/\/shipcare.jp\/crankcase-explosive-conditions-monitoring-system-neuenhauser-kompressorenbau-gmbh-tufmon-mev282-and-mev283\/","title":{"rendered":"Crankcase Explosive Conditions Monitoring System NEUENHAUSER KOMPRESSORENBAU GMBH TUFMON MEV282 and MEV283"},"content":{"rendered":"

NEUENHAUSER KOMPRESSORENBAU GMBH<\/strong> Genuine & OEM spare parts made in Japan, China, Korea and Europe for Maritime, Oil & Gas Industry.
\nContact us<\/strong> if you are looking for Crankcase Explosive Conditions Monitoring System TUFMON MEV282 and MEV283<\/strong> marine equipment and ship spare parts.<\/p>\ninfo@shipcare.jp<\/span><\/a>\n\n

<\/i> Equipment:<\/strong> Crankcase Explosive Conditions Monitoring System
\n<\/i> Manufacturer:<\/strong> NEUENHAUSER KOMPRESSORENBAU GMBH
\n<\/i> Type \/ Model \/ Part no:<\/strong> TUFMON MEV282 and MEV283<\/p>\n

<\/i> Technical Specification & Spare Parts: <\/strong>
\nTUFMON MEV282 and MEV283 Crankcase Explosive Conditions Monitoring System NEUENHAUSER KOMPRESSORENBAU GMBH
\nInstrumentation and Automation,
\nCrankcase Explosive Conditions Monitoring System, <\/p>\n

Crankcase Explosive Conditions Monitoring System, <\/p>\n

MEV282xxx Compact Oil Mist Detector type TGL015xxx\/TGL017xxx\/TGL018xxx Power supply: 24VDC Degree of protection: Analyzer box: IP56, optical sensor IP67 Display: Failure LED Outputs: analog 4\u202620mA, galvanic isolated; relay outputs, max switching voltage 125VAC\/DC. MEV283xxx\u2026 Compact Oil Mist Monitoring System Power supply: 2 x 24VDC Degree of protection: Monitoring box: IP67, optical sensor: IP67 External Input: Engine signal (on\/off) Analog outputs: 4\u202620mA for crankcase pressure and oil mist level 1 Alarm\/Trip Relay, NO\/NC free programmable, max. switching voltage 220VDC, 250VAC, 2A DC\/AC 1 System Error Relay, self-monitoring short-circuit protected, configurable 3 Status Message Relays, short-circuit protected, configurable, max. switching voltage 7\u202660V AC\/DC Communication interfaces: Ethernet; CAN (galvanic isolated), CANopen, J1939. MEV282xxx and MEV283xxx crankcase pressure sensor configuration: -xxx=013: without pressure sensor and with customer designed measuring tube type TGL015xx -xxx=113: external pressure transducer, customer designed measuring tube TGL017xx\/018xx -xxx=203: internal pressure transducer 0\u202625mbar, customer designed measuring tube TGL017xx\/018xx -xxx=213: internal pressure transducer -25\/25mbar, customer designed measuring tube GL017xx\/018xx SW-Versions: -MEV282: V1.15, dated 2013-04-04 -MEV283: V2.26, dated 2019-02-05,<\/p>\n

Contact our Customer Care Center<\/strong> today for quotations and orders.
\nShipcare+ Japan
\n
info@shipcare.jp<\/a>
\n
www.shipcare.jp<\/a><\/p>\n","protected":false},"excerpt":{"rendered":"

NEUENHAUSER KOMPRESSORENBAU GMBH Genuine & OEM spare parts made in Japan, China, Korea and Europe for Maritime, Oil & Gas Industry. Contact us if you are [\u2026]<\/span><\/p>\n","protected":false},"author":1,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[4],"tags":[30296],"_links":{"self":[{"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/posts\/575713"}],"collection":[{"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/comments?post=575713"}],"version-history":[{"count":0,"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/posts\/575713\/revisions"}],"wp:attachment":[{"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/media?parent=575713"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/categories?post=575713"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/shipcare.jp\/wp-json\/wp\/v2\/tags?post=575713"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}